During the winter, problems with freezing in fresh water, waste water, cooling water, supply water and sprinkler systems can be avoided by internal or external pipe heating.
Pipes installed outdoor or inside unheated premises, even if insulated, can be subjected to low temperatures that result in ice generation inside pipes.
Electric heating cables
DEVI heating system provides a versatile solution for water pipes protection (including drinking water pipelines) against freezing.
For on-pipe application: DEVIflex™ constant wattage cables or self-limiting cables such as DEVIpipeguard™, provide flexible and on-site cut-to-length solutions.
For in-pipe application: DEVIaqua™ constant wattage cables or self-limiting cables such as DEVIpipeheat™ 10 V3.
Also, for the fire sprinkler system, DEVI company can offer The DEVIpipeguard™ LSZH, which is a halogen free.
To be eligible for the 20-year full warranty on resistive cables and 5- or 10-year product warranty on self-limiting cables, the installation must be documented in accordance with the manufacturer's instructions - either via the e-Warranty app or manually.
To avoid problems, be sure to read the instructions and manuals of the supplier.
Thermostats or controllers
The system should be regulated by electronic thermostats. This is required for both constant wattage cables and self-limiting cables to prevent overheating and power consumption during standby periods.
For single pipes, analogue thermostats can be used such as DEVIreg™ 330 or DEVIreg™ 610.
For multi pipe networks, DEVIreg™ Multi can be used, channel electronic programmable controller which can be installed on DIN rail. Every channel can be individually set up with three control modes –with temperature sensor, time proportional power regulation without sensor and manually on/off with time limitation.
One of the main advantages is Modbus RS485 opto-insulated serial interface gives possibility for BMS control.
Accessories
DEVIreg 850 IV moisture sensor
The roof sensor measures both parameters on the sensor surface:
- temperature
- moisture from ice, snow, hail or rain
These measurements are sent to the DEVIreg™ 850 IV, and it decides how the ice and snow melting system should control the heated areas.
More information on controller settings can be found in the DEVIreg 850™ IV installation manual.
DEVIconnecto™
The DEVIconnecto program gives you different solutions for easy and safe connection of DEVI self-limiting heating cables.
Using DEVIconnecto to wire up a heating circuit is fast, requiring only a knife and a diagonal cutter.
Always use only authorized accessories from DEVI.