Accessories
To effectively support our customers and partners, DEVI offers a wide range of accessories and tools that make the installation of electric heating systems easier and faster, in line with our motto: "Make it easy, make it DEVI." The right accessories not only enhance installation comfort but, more importantly, increase the safety of the system and its users. Therefore, it is essential to choose original DEVI products to ensure the system's reliability and user safety.
Benefits
- Original parts
- Safety for users
- Easy installation
- Properly selected components
- High quality
- Proven solutions
Product variants
Choose a product variant to go for product page on Danfoss Store, where you can find more details and documents
|
Art. no. |
Product name |
Description/Technical data |
|---|---|---|
|
Outdoor sensor IP44 |
80 х 50 х 35 mm, NTC 15 kOhm at 25 °C, IP 44 |
|
|
Sensor cable 3 m, 15 kOhm, Santropene |
Wire sensor 2x0,75 mm², NTC 15 kOhm at 25 °C, Ø5 mm, black Santropene (TPV) outer sheath, IP 67, Temp. range -25 °C to 90 °C |
|
|
Temperature Sensor 10 m NTC 15k Santropene |
Temperature Sensor 10 m NTC 15k Santropene |
|
|
Outdoor sensor 2,5 m, 15 kOhm, PVC, DIN 44574 |
Wire sensor, 2x0,75 mm², NTC 15 kOhm at 25 °C, Ø10 mm, white PVC outer sheath, IP 67, Temp. range -25 °C to 70 °C |
|
|
Silicon temperature sensor for DEVIreg™ 330 (60-160°C) |
Wire sensor, 2,5 m, 2x0,75 mm², NTC 16,1 kOhm at 100 °C, Ø9 mm, IP 65, Temp. range 50 °C to 170 °C |
|
|
Sensor end-cap brass for Flexpipe Ø6,7 mm |
Package 60 x Ø12 mm, size 60 x Ø12 mm, inner Ø6,7 mm, inner Ø10 mm |
|
|
Sensor tube and cap for DEVIreg™ 850 |
Installation tube for Ground Sensor DEVIreg™ 850, Ø 93 х 98 |
|
|
PSU CP-D 24/2.5 100-240VAC/24VDC DINrail |
Primary switch mode Power Supply Unit for DEVIreg 850. Input voltage 100-240 VAC, 47-63 Hz, Output voltage 24 VDC, Output current/power max 2,5 A / 60 W |
|
|
DEVIreg™ 233 Front, knob 1 pcs. in box, White |
1 pcs. in box, White |
|
|
DEVIconnecto B-X, X-Junction + 2 End termination |
130 x 265 x 75 mm |
|
|
DEVIconnecto Bracket, ref AH 61400005 |
Bracket for installation outside the insulation. Length 194 mm, high 55 mm, width 30 mm. |
|
|
DEVI EasyConnect EC-1 Power connection |
Power supply connection set |
|
|
DEVI EasyConnect EC-T1 Heating cable connection |
Connection set for 2 heating cables |
|
|
DEVI EasyConnect EC-ETK End termination |
End plug set |
|
|
DEVI EasyConnect EC-1 +ETK Power con. + end term. |
Power supply connection set with an end plug |
|
|
DEVI EasyConnect EC-T2 Heating cable con x 2 |
Set for heating cable branching – 1 to 2 |
|
|
DEVI EasyConnect EC-2 Power connection x 2 |
Power supply connection set for 2 cables |
|
|
DEVI EasyConnect EC-3 Power connection x 3 |
Power supply connection set for 3 cables |
|
|
Anschlussgarnitur fuer poestergehause |
Connection set with end-cap for connection self-limiting cables to junction box or connection housing and assembly end-termination. |
|
|
Insulation introduction Cable gland M20/M25 |
For self-limiting cables DEVIiceguard™, DEVIpipeguard™, DEVIhotwatt™. |
|
|
Flathole packing PG16 for self-limiting cables |
For cable gland M25 for self-limiting cables DEVIiceguard™, DEVIpipeguard™ and DEVIhotwatt™. Size: ø20×6 mm. |
|
|
Junction box 0,75-2,5 mm² 7xM20 |
Box for indoor installation. Rated insulation voltage Ui = 690 V AC/DC, Rated current 20 A. |
|
|
Junction box 1,5-4 mm² 7xM20/M25 UV |
Weatherproof box for outdoor installation. Rated current 32 A. IP 66/IP 67/IP 69. |
|
|
Bracket Fitting for connection of housing or junction box to pipes |
Fitting for connection of housing or junction box to pipes. |
|
|
Spaceclip for self-limiting cables |
300 x 5 x 70 mm |
|
|
DEVIconnecto B-A Connection |
Connection package 130 x 265 x 75 mm |
|
|
DEVIconnecto B-C Heating cable connection |
Heating cable connection package 130 x 265 x 75 mm |
|
|
DEVIconnecto B-E End termination |
End termination package 130 x 265 x 75 mm |
|
|
DEVIconnecto B-S Connection termination |
Connection termination package 130 x 265 x 75 mm |
|
|
DEVIconnecto B-T, T-Junction + End termination |
T-Junction + End termination package 130 x 265 x 75 mm |
|
|
DEVIconnecto B-TE2 Junction + 2 End termination |
Junction + 2 End termination package 130 x 265 x 75 mm |
|
|
DEVIconnecto B-TE3 Junction + 3 End termination |
Junction + 3 End termination package 130 x 265 x 75 mm |
|
|
Connection kit for DEVIpipeguard™ 30/60 Industry heating cables |
With clamping block for the connection of cold lead and heating cable, shrink end-cap, shrink tubes, bitumen gaskets and ferrules. |
|
|
Connection kit for DEVIpipeguard™ 30/60 Industry heating cables (box mounting) |
For mounting in connection box with crew connections. With cable gland M20x1,5 with locknut, shrink end-cap, shrink tubes, bitumen gasket and ferrules. |
|
|
Connection kit - cable to junction box + end termination (Pipeheat) |
Connection set with end-cap for connection DEVIpipeheat™ 10 V2 and V3 to junction box or connection housing and assembly end-termination. |
|
|
Connection kit - cable to cold lead + end termination (Pipeheat) |
Connection set with end-cup for assembly between DEVIpipeheat™ 10 V2 and V3 and cold lead/SLC and assembly end-termination. |
|
|
3/4”+1” Pipe Fitting DEVIpipeheat™ 10 V3 |
Wadding for Internal mounting In pipe for DEVIpipeheat™ 10 V3. |
|
|
Con. Kit, cable/box self-limiting cables |
Connection set with end-cap and flathole packing for connection DEVIpipeguard™, DEVIiceguard™ or DEVIhotwatt™ to junction box or connection housing and assembly end-termination. |
|
|
Con. Kit, cable/cold tail self-limiting cables |
Connection set with end-cap for assembly between DEVIpipeguard™, DEVIiceguard™ or DEVIhotwatt™ and cold lead/SLC and assembly end-termination. |
|
|
Con. Kit, cable/cable self-limiting cables |
Fitting set for joining of self-limiting cables DEVIpipeguard™, DEVIiceguard™, DEVIhotwatt™ to self-limiting cable. |
|
|
DEVIcrimp™ t-connection for self-limiting cables |
Fitting set for joining of 1 self-limiting cable DEVIpipeguard™, DEVIiceguard™ or DEVIhotwatt™ to 2 self-limiting cables with T-connection. |
|
|
ANSCHLGAR. M/KLEM Z.VERB.VON FLEXIB. |
Connection set with clamping block and with end-termination for assembly between DEVIpipeheat™, DEVIhotwatt™, DEVIiceguard™ and cold lead. |
|
|
Endcap Shrinkfit End-cap TEC12-4 |
Package 245 x 10 x 170 mm 1 pc. in a bag. |
|
|
Tape aluminium 38 mm x 50 m |
Self-adhesive, with 2-colour warning text, max. 160 °C |
|
|
DEVI turntable™ Ø400 x 70 mm |
1 pc. |
|
|
Fastening for down pipes |
Cable fixing for down - pipe suspension Dimensions - 37 х 20 х 6 mm Chain hole size - 8 mm 1 bag with 25 pcs. |
|
|
Longlinked chain 4 mm c4 x 32 din 5685 fzn |
Chain hole size - 8 mm Cut-to-length - 1...25 m |
|
|
Traverse v 2 a |
Dimensions - 288 x 25 x 5 mm |
|
|
DEVIfast™ Metal 5 m |
Width - 21 mm Material - Galvanized Metal covered by galvanized zinc Cable C-C fixing - in each 25 mm |
|
|
DEVIfast™ Metal 25 m |
Width - 21 mm Material - Galvanized Metal covered by galvanized zinc |
|
|
DEVIfast™ Copper 25 m |
Width - 21 mm Material - Copper Cable C-C fixing - in each 25 mm |
|
|
DEVIclip™ roofhook, installation kit |
Roofhook - 25 pcs. Cable Strip 7,6x203 mm, black - 25 pcs. |
|
|
DEVIclip™ guardhook Install. kit |
Base Roof accessories - 20 pcs. Angle Roof accessories - 10 pcs. Cable Strip 7,6x203 mm, black - 30 pcs. |
|
|
Roof Gutter Clip with hinge |
1 bag with 25 pcs. |
|
|
DEVIclip™ c-c |
500 x 50 x 60 mm, 20 pcs. in bag. |
|
|
DEVIclip™ Twisto |
Plastic Bag with 1000 pcs. |
|
|
Montagestege type ms 6,6-8,0 mm |
1000 x 10 x 10 mm |
|
|
Flexkit for DEVIcell™ |
Package 170 x 250 x 20 mm |
|
|
EPS-Randplatten W25 DEVIcell™ L100 |
Size - 1000x250x15 mm Plastic type - EPS Max working temp. - 85˚C Deformation strength >120 kPa at 10% compression |
|
|
Wall mounting for DEVItemp™ cabin A |
Package 280 x 40 x 130 mm |
|
|
Wall mounting for DEVItemp™ cabin B |
Package 360 x 150 x 40 mm |