DEVIiceguard™ 18 (B) Drum Goods

DEVIiceguard™ 18 is a self-limiting parallel heating cable designed for ice and snow melting applications on roofs, in gutters, and in downpipes. The cable adjusts its heat output according to the surrounding temperature conditions, helping maintain effective operation in varying weather conditions.
 
The heating cable can be cut to the required length during installation and fitted directly onto roof and gutter systems. DEVIiceguard™ heating cables must not be installed in direct contact with bitumen roofs.
 
All self-limiting heating cables require over-temperature protection provided by a thermostat. As the cable continues to generate heat output, although at a reduced level, protection by an RCD with a maximum trip current of 30 mA is required.
 
*An Environmental Product Declaration (EPD) is a document that reports quantified environmental impacts of a product across defined life cycle stages.
DEVIiceguard™ 18 (B) Drum Goods

Benefits

  • Can be cut to the required length on site
  • Heat output adapts to ambient temperature conditions
  • Suitable for installation in roofs, gutters, and downpipes
  • Supports roof de-icing and snow melting applications
  • Compatible with thermostat-controlled protection systems

Specification

Nominal voltage

230 V AC

Nominal output

18 W/m @ 0 °C

Output tolerance (min-max)

15,4-23,1 W/m @ 10 °C

Maximum permissible use temperature

65 °C, powered
85 °C, unpowered

Minimum installation temperature

-5 °C

Cable dimensions

11,8 mm x 5,8 mm (+/- 0,4 mm)

Outer sheath

UV protected, black TPE

Screen

Tinned copper braid, 1,25 mm2

Minimum braid coverage

80%

Maximum resistance protective braid

14,8 Ω/Km

Bending Ø, min.

50 mm (Ø to the inside of the cable)

IP Class

IPX7

Compliance

Standard compliance: EN 62395-1: 2013

Compliance

GARAN Label

Product variants

Choose a product variant to go for product page on Danfoss Store, where you can find more details and documents

Item no.

Length

Min-max length per drum

Number of length allowed
on drum, max

Nominal output @ 0 °C

98300810

Drum, 100 m

100 m

1

18 W/m

98300809

Drum, 300 m

300 m

1

18 W/m

140F8512

Drum, 800 m

800 m

1

18 W/m

140F8513

Cut-to-length

1 - 800 m

1, max. 800 m

18 W/m

Documents