DEVIiceguard™ 18 (T) Drum Goods
The DEVIiceguard™ is a self-limiting parallel heating cable that is used for ice and snow melting on roofs and in gutters and downpipes. DEVIiceguard™ heating cables should not be in direct contact with bitumen roofs.
The self-limiting capability of the cable ensures that the output of the cable increase or decrease according to ambient temperature.
The heating cable is flexible and easy to install as it can be cut to length at site and installed directly on to the roof and gutter system. All self-limiting heating cables must be over-temperature protected by a thermostat, as the output will decrease, but never be zero, and be protected by a RCD with a maximum trip current of 30 mA.
Benefits
- Easy to install
- Cut to length on site
Specification
Nominal voltage |
230 V AC |
Nominal output |
18 W/m @ 0 °C |
Output tolerance (min-max) |
15,4-23,1 W/m @ 10 °C |
Maximum permissible use temperature |
65 °C, powered |
Minimum installation temperature |
-5 °C |
Cable dimensions |
11,8 mm x 5,8 mm (+/- 0,4 mm) |
Outer sheath |
UV protected, black TPE |
Screen |
Tinned copper braid, 1,25 mm2 |
Minimum braid coverage |
80% |
Maximum resistance protective braid |
14,8 Ω/Km |
Bending Ø, min. |
50 mm (Ø to the inside of the cable) |
IP Class |
IPX7 |
Warranty scope
Compliance
Standard compliance: EN 62395-1: 2013
Product variants
Choose a product variant to go for product page on Danfoss Store, where you can find more details and documents